EN 60730 Test Methods for Automatic Electrical Controls

Electric Electronic Tests

EN 60730 Test Methods for Automatic Electrical Controls

EUROLAB laboratory provides testing and compliance services within the scope of EN 60730 standard. The EN 60730 standard applies to automatic electrical controls for use in, on, or in combination with equipment for household and similar use. The equipment can be used for electricity, gas, oil, solid fuel, solar energy, etc. or a combination of these.

EN 60730 Test Methods for Automatic Electrical Controls

This International Standard applies to controls for building automation under ISO 16484. This standard also applies to automatic electrical controls of equipment that may be used by the public, such as equipment intended for use in shops, offices, hospitals, farms, and commercial and industrial applications.

This standard is also applicable to individual controls used as part of a control system, or to controls mechanically integrated with multifunction controls with non-electrical outputs. This standard can also be applied to relays when used as controls for EN 60335 devices.

This standard is intended to be used for the testing of any stand-alone relay intended to be used as a control of a device according to EN 60335-1. It is not intended to be used for any other stand-alone relay or to replace the EN 61810 series standards.

This standard does not apply to automatic electrical controls for industrial process applications only, unless expressly stated in the equipment standard. This standard applies to controls powered by primary or secondary batteries whose requirements are included in the standard.

This International Standard applies to structural safety, operating values, operating times and sequences of operation, and testing of automatic electrical control devices used on or with equipment where it relates to equipment safety. This standard applies to controls using thermistors.

This standard can also be applied to the functional security of security-related low complexity systems and controls. This standard covers mechanical or electrically operated automatic electrical controls that respond to or control properties such as temperature, pressure, the passage of time, humidity, light, electrostatic effects, flow or liquid level, current, voltage, acceleration or combinations thereof.

This standard applies to starter relays, a specific type of automatic electrical control intended to change the starter winding of a motor. Such controls may be integrated into or separate from the motor. Start relays are tested as voltage sense or current sense controls.

This standard applies to manual controls that are electrically or mechanically integrated with automatic controls. This standard applies to ac or dc powered controls with a rated voltage not exceeding 690 V ac or 600 V dc.

This standard does not take into account the response value of a control's automatic action if such a response value is dependent on the way the control is mounted to the equipment. Where a response value has an important purpose to protect the user or their environment, the value defined in the appropriate household equipment standard or specified by the manufacturer will apply.

This standard applies to the electrical and functional safety of controls capable of receiving and responding to communication signals, including signals for power billing rate and demand response. Signals can be transmitted to or received from external units that are part of the control (wired) or external units that are not part of the control under test (wireless).

This standard does not address the integrity of the output signal to network devices, such as interoperability with other devices, unless considered as part of the control system. The EN 60730 test standard tests automatic electrical controls in 2 separate sections:

EN 60730-1 Automatic Control Schemes - Part 1: General Requirements

This part of the EN 60730 standard covers the general rules applied to electrical automatic control devices used in households and similar places.

EN 60730-2-1 Automatic Control Schemes - Part 2-1: Electrical Controls for Electrical Appliances

This part of the EN 60730 standard covers controls with a rated voltage of 660V and a rated current not exceeding 63A.

EN 60730-2-2 Automatic Control Schemes - Part 2-2: Special Requirements for Thermal Motor Protectors

This part of the EN 60730 standard applies to the partial evaluation of thermal motor protectors for domestic and similar uses, including heating, air conditioning and similar applications.

EN 60730-2-3 Automatic Control Schemes - Part 2-3: Special Requirements for Thermal Protectors for Ballasts for Tubular Fluorescent Lamps

This part of the EN 60730 standard applies to the evaluation of thermal protectors of tubular fluorescent lamps.

EN 60730-2-4 Automatic Control Schemes - Part 2-4: Special Rules for Thermal Motor Protectors of Hermetic End Motor Compressors

This part of the EN 60730 standard covers the evaluation of thermal motor protectors for hermetic end motor compressors.

EN 60730-2-5 Automatic Control Schemes - Part 2-5: Special Rules for Automatic Electric Burner Control Systems

This part of the EN 60730 standard applies to automatic electric burner control systems for the automatic control of oil, gas, coal or other combustible materials for household and similar uses, including heating, air conditioning and similar uses.

EN 60730-2-6 Automatic Controls - Part 2-6: Special Rules for Electric Automatic Pressure Sensitive Controls, Including Mechanical Rules

This part of the EN 60730 standard covers electricity, gas, oil, solid fuel, solar thermal energy, etc. Automatic, electrical, electrical, automatic, electrical, and electrical equipment with a minimum rated pressure value of -60 kPa and a maximum measurement pressure value of 4,2 MPa in, on or associated with equipment in household and similar applications, including heaters, air conditioners and similar devices, that use or use a combination of these. includes pressure sensitive control schemes.

EN 60730-2-7 Automatic Control Schemes - Part 2-7: Special Rules for Timers and Time Switches

This part of the EN 60730 standard is used for heating-ventilation etc. used in houses and similar places. It covers the timers and time switches in their facilities.

EN 60730-2-8 Automatic Control Schemes - Part 2-8: Special Rules for Electrically Operated Water Valves, Including Mechanical Rules

This part of the EN 60730 standard covers electrically driven water for domestic and similar use using electricity, gas, gasoline, solid fuel, solar heating energy or a combination thereof, in, on, or in conjunction with equipment, including heating, air conditioning and similar applications. covers the valves.

EN 60730-2-9 Automatic Control Patterns - Part 2-9: Special Rules for Temperature Sensing Control Patterns

This part of the EN 60730 standard covers automatic electrical temperature sensing control schemes for use in, on, or in conjunction with household and similar equipment, including electrical control schemes for heating, air conditioning and similar applications.

EN 60730-2-11 Automatic Control Schemes - Part 2-11: Special Requirements for Energy Regulators

This part of the EN 60730 standard applies to domestic automatic controls. This standard is applied to electrical energy regulators in household and similar type equipment and heating, air conditioning and similar devices.

EN 60730-2-12 Automatic Control Schemes - Part 2-12: Special Rules for Electric Door Locks

This part of the EN 60730 standard covers electric door locks used in homes and similar places.

EN 60730-2-14 Automatic Control Schemes - Part 2-14: Special Requirements for Electric Actuators

This part of the EN 60730 standard, including use in home and air conditioning and systems, or school training, which is school. This equipment can be purchased for electricity, gas, gasoline, solid fuel, solar thermal energy, etc. or one.

EN 60730-2-15 Automatic Controls - Part 2-15: Special Rules for Water Level Sensitive Automatic Electrical Controls of the Float or Electrode Sensing Type Used in Boiler Applications

This part of the EN 60730 standard covers float and electrode sensor type water level sensitive automatic electrical control devices for household and similar use.

EN 60730-2-19 Automatic Control Schemes - Part 2-19: Special Requirements for Electrically Operated Oil Valves, Including Mechanical Requirements

This part of the EN 60730 standard covers distillates, residual fuels, etc. This applies to electrically operated oil valves for use on, on, or in conjunction with household and similar equipment that uses electricity with liquid fuel, such as This part 2 also applies to electrically operated oil valves using NTC or PTC thermistors whose requirements are in Annex J.

EUROLAB, with its more than 25 years of experience, state-of-the-art accredited laboratories and expert team, helps you get precise and fast results. Do not hesitate to contact our laboratory for your testing and certification requests.

Get Offer Now

To get an appointment, to get more detailed information or to request an evaluation, you can ask us to fill in our form and reach you.