UL 510 Polyvinyl Chloride - Standard for Polyethylene and Rubber Insulation Tape

Electric Electronic Tests

UL 510 Polyvinyl Chloride - Standard for Polyethylene and Rubber Insulation Tape

EUROLAB, with its state-of-the-art accredited laboratories and expert team, provides precise and fast testing services within the scope of UL 510 testing. This standard applies to thermoplastics and rubbers used as electrical insulation at 70°C (600°F) and below, not more than 80 V at splices and splices in wire and cable, in accordance with the National Electrical Code ANSI/NFPA 176. covers the bands. The rubber band on a joint or joint is intended to be mechanically protected by a cover such as friction tape. Thermoplastic tape is acceptable without additional mechanical protection.

UL 510 Polyvinyl Chloride - Standard for Polyethylene and Rubber Insulation Tape

UL 510 is a US norm called "Standard for Safety of Insulating Sleeving". This standard specifies the specifications and tests required by insulating suede for the safety of electrical and electronic equipment. For example, properties of insulation suede such as fire resistance, heat resistance, high voltage resistance and mechanical durability are tested according to the UL 510 standard. This standard aims to ensure the safety of devices during production and use.

Certain components lack construction features or have limited performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures that do not exceed specified limits, and should only be used under these special conditions.

The samples to be tested shall be marked with a marker consisting of a parallel-bladed stamp capable of forming fine lines with ink on a sample without damaging the tape. The lines (benchmarks) shall be 2 inches (50 mm) apart and applied at right angles to the constricted portion of the specimen and to the specimen's longitudinal axis. The elongation measurement should be made relative to the center of each mark, ie the middle of the edges.

The specimen shall be clamped in position with 2 inch (50 mm) gauge marks both on the outside of the jaws and between the jaws. The movable handle should be adjusted so that the sample is taut but not under tension. The temperature of the ambient air should be observed and recorded.

EUROLAB assists manufacturers with UL 510 test compliance. Our test experts, with their professional working mission and principles, provide you, our manufacturers and suppliers, the best service and controlled testing process in our laboratories. Thanks to these services, businesses receive more effective, high-performance and quality testing services and provide safe, fast and uninterrupted service to their customers.

Get Offer Now

To get an appointment, to get more detailed information or to request an evaluation, you can ask us to fill in our form and reach you.

WhatsApp