IEC EN 60051-4 Analogue Electrical Measuring Devices with Direct-Act Display and Their Accessories Title - Part 4: Special Requirements for Frequency Meters

Electric Electronic Tests

IEC EN 60051-4 Analogue Electrical Measuring Devices with Direct-Act Display and Their Accessories Title - Part 4: Special Requirements for Frequency Meters

EUROLAB, with its state-of-the-art accredited laboratories and expert team, provides precise and fast testing services within the scope of IEC EN 60051-4 testing. IEC EN 60051-4 applies to analog frequency meters with direct-acting display of the following types: IEC EN 60051-4 also applies to non-replaceable accessories used with frequency meters.

IEC EN 60051-4 Analogue Electrical Measuring Devices with Direct-Act Display and Their Accessories Title - Part 4: Special Requirements for Frequency Meters

  • Pointer type frequency meters;
  • Vibrating frequency meters.

The reference value for a frequency meter corresponds to:

  • The upper limit of the measuring range;
  • For vibratory reed frequency meters with several rows of reeds, each row is considered a separate range, and each row has its own reference value, which is the upper limit of the measuring range of that row.

Frequency meters, with non-replaceable accessories, if any, must be subjected to a continuous voltage overload of 120% of the rated voltage or 120% of the upper limit, excluding instruments equipped with a non-locking switch.

After cooling to reference temperature, the frequency meter, with any non-replaceable accessories, must comply with accuracy requirements; however, the overload will not be repeated.

Frequency meters with non-replaceable accessories, if any, will be subjected to short-term overvoltage loads. Voltage ratings for short-term overloads should be the product of the rated voltage or the upper limit of the rated range for voltage, unless other values ​​are specified by the manufacturer.

After being subjected to short-term overloads and cooling to the reference temperature, the frequency meter and its non-replaceable accessories, if any, must meet the accuracy requirements; however, overloads should not be repeated.

EUROLAB assists manufacturers with IEC EN 60051-4 test compliance. Our test experts, with their professional working mission and principles, provide you, our manufacturers and suppliers, the best service and controlled testing process in our laboratories. Thanks to these services, businesses receive more effective, high-performance and quality testing services and provide safe, fast and uninterrupted service to their customers.

Get Offer Now

To get an appointment, to get more detailed information or to request an evaluation, you can ask us to fill in our form and reach you.

WhatsApp