EN 12259-2 Components for Sprinkler and Water Spray Systems - Wet Alarm Valve Assemblies

Product Safety Tests

EN 12259-2 Components for Sprinkler and Water Spray Systems - Wet Alarm Valve Assemblies

EUROLAB, with its state-of-the-art accredited laboratories and expert team, offers precise and rapid testing services within the scope of EN 12259-2 testing. This standard covers the rules regarding the structure and performance of wet alarm valve assemblies and delay chambers used in automatic sprinkler systems. Auxiliary components and connections of wet alarm valve assemblies and delay chambers are not covered by this standard.

EN 12259-2 Components for Sprinkler and Water Spray Systems - Wet Alarm Valve Assemblies

Any reciprocating guide component in the main valve body that is required to operate to enable the wet alarm valve to open shall have a minimum diameter clearance of not less than 0,7 mm at the portion where the movable component enters the fixed component. and not less than 0,05 mm on that part of the moving component that is in permanent contact with the stationary component in readiness.

A filter shall be installed when the diameter of the water passages in the delay chamber is 6 mm or less. The maximum size of openings in the strainer shall not be more than two-thirds the diameter of the smallest water passage to be protected by the strainer. The total cross-sectional area of ​​the openings in the strainer shall not be less than twenty times the cross-sectional area of ​​the water passages.

The retardation chamber shall contain means for its support. If pipe is to be used for this support, the size of pipe to be used and the maximum length of pipe so used shall be specified in the instruction sheets supplied with the delay chamber.

The delay chamber shall be equipped with means for automatic discharge. The time it takes for the delay chamber to be completely filled with water and discharged to the atmosphere, including the relevant trim specified by the manufacturer, shall not exceed 5 minutes.

Installation and operating instructions shall be provided with each wet alarm valve and each delay chamber. These will include a drawing showing the recommended mounting method and trim function, images illustrating mounting views and operation, and maintenance and repair recommendations.

EUROLAB assists manufacturers with EN 12259-2 test compliance. Our test experts, with their professional working mission and principles, provide you, our manufacturers and suppliers, the best service and controlled testing process in our laboratories. Thanks to these services, businesses receive more effective, high-performance and quality testing services and provide safe, fast and uninterrupted service to their customers.