DIN 4109 and EN ISO 10052 Sound Insulation and Acoustic Tests

Product Sufficiency Tests

DIN 4109 and EN ISO 10052 Sound Insulation and Acoustic Tests

The range of building acoustics measurements ranges from determining the soundproofing properties of building components and systems to measuring noise from sanitary facilities and building service equipment. Our services cover almost all standard measurement methods in the field of building acoustics and sound emission protection. EUROLAB Laboratory has more than 10 test rooms and laboratories for this purpose.

DIN 4109 and EN ISO 10052 Sound Insulation and Acoustic Tests

The sound insulation regulation DIN 4109 defines the minimum requirements for sound insulation in building construction. This regulation applies to windows and doors. DIN 4109 defines six sound insulation classes. The sound reduction index, which defines the sound insulation of an installed window or front door, is decisive for classification in a sound insulation class. The respective sound insulation classes are the limits corresponding to a certain traffic volume at a certain distance.

Building acoustics measurements in the laboratory

Within the scope of building acoustics measurements in our laboratories, we offer various services such as air/impact sound insulation from skylights and skylights and rain noise measurement (DIN EN ISO 10140). We also measure the lateral transmission of airborne and impact sound between adjacent rooms (DIN EN ISO 10848), evaluate and test the airborne sound insulation properties of exterior building components at our façade test facility (DIN EN ISO 16283-3). characterizes the acoustic properties of insulating elements for solid stairs (DIN 7396). In addition, by determining the sound absorption coefficients and equivalent sound absorption area in our reverberation room, we make sound power measurements according to the surrounding surface, echo chamber and sound intensity methods.

  • DIN EN ISO 10140: Measurement of air or impact sound insulation of building components
  • DIN EN ISO 10140: Measurement of rain noise from skylights and skylights
  • DIN EN ISO 10848: Measurement of lateral transmission of airborne and impact sound between adjacent rooms
  • DIN EN ISO 16283-3: Airborne sound insulation of exterior building components in a façade test facility
  • DIN 7396: Test methods for acoustic marking of insulating elements for solid stairs
  • DIN EN ISO 354 and DIN EN ISO 11654: Sound absorption coefficient and equivalent sound absorption area in the reverberation chamber
  • DIN EN ISO 3741, DIN EN ISO 3745, DIN 45635, ISO 9614, etc.: Determination of the sound power level using the enveloped surface method, echo chamber and sound intensity method.


Acoustic properties of building materials
To evaluate the acoustic properties of building materials, we measure, among others, dynamic stiffness (DIN EN 29052), length-related airflow resistance (DIN EN 29053) and dynamic-mechanical properties (DIN EN ISO 6721). More customized measurements are available on request.

  • DIN EN 29052: Dynamic stiffness
  • DIN EN 29053: Length-dependent airflow resistance
  • DIN EN ISO 6721: Dynamic-mechanical properties


Noise from plumbing and building service equipment

When it comes to noise from sanitary ware and building service equipment, we examine the noise caused by water supply valves (DIN EN ISO 3822), sewer noise (DIN EN 14366) and sound levels of sanitary facilities installed in prototype test facilities. (DIN EN ISO 10052 and others). We also measure level differences between airborne and impact sound (DIN 52210-6), structure-borne noise from building service equipment (DIN EN 15657), and sound levels from service equipment in buildings (DIN EN 12354-5).

  • DIN EN ISO 3822: Water supply valves
  • DIN EN 14366: Noise of wastewater systems
  • DIN EN ISO 10052, SIA 181, etc.: installation sound levels of sanitary facilities installed in prototype test facilities
  • DIN 52210-6: Measurement of shaft level difference
  • DIN EN 15657: Measurement of building service equipment noise from the structure
  • DIN EN 12354-5: Calculation of installation noise in buildings


Sound emission protection

As part of sound emission control, we inspect noise barriers in the laboratory and on site (DIN EN 1793-1 to -6 and others) and test them for noise emission (according to "TA Lärm") and vibration protection (DIN). 4150).

  • DIN EN 1793-1 bis 6, ZTV-Lsw 06, DB-Ril. 804.5501, etc.: Noise barriers in the laboratory and on-site
  • “TA-Lärm”: Noise emission protection
  • DIN 4150: Vibration control


Acoustic measurements in buildings

We are also experts in measuring acoustics in buildings where we evaluate air and impact sound insulation between rooms (DIN EN ISO 16283-1 and -2), airborne sound insulation of facades (DIN EN ISO 16283-3 et al.). , reverberation times (DIN EN ISO 3382), sound level of installed sanitary facilities and airborne noise levels from building service equipment (DIN EN ISO 10052 / DIN 4109).

  • DIN EN ISO 16283-1 Airborne sound insulation between rooms
  • DIN EN ISO 16283-2 Impact sound insulation between rooms
  • DIN EN ISO 16283-3, DIN EN ISO 15186 Airborne sound insulation of facades
  • DIN EN ISO 3382 Reverberation time
  • DIN EN ISO 10052 / DIN 4109
  • Sound level of installed sanitary facilities and airborne sound levels of building service equipment

As building acoustics measurements usually require component and system tests recognized by building code or conformity and quality tests according to DIN 4109, EUROLAB tests all of the above and many others; in our independent, accredited testing laboratory.

Get Offer Now

To get an appointment, to get more detailed information or to request an evaluation, you can ask us to fill in our form and reach you.

WhatsApp